Illustrated title card for the guide: Best Pure Sine Wave UPS Models for NUT usbhid-ups

buying guides

Best Pure Sine Wave UPS Models for NUT usbhid-ups

Compare three pure sine wave UPS models with NUT usbhid-ups support, check their outlets and watt ratings, and verify shutdown features over USB.

Start with the CyberPower CP1500PFCLCDa for a 120 V tower. For 230 V, choose the CyberPower CP1500EPFCLCD if you need Schuko outlets or the Eaton 5SC2200IRT if you need a rack-mount unit. Compare their power ratings and reported support in Network UPS Tools (NUT) below.

Pure sine wave UPS shortlist

Best fitModelPower and outletsWhat NUT reports show
120 V towerCyberPower CP1500PFCLCDa1,500 VA / 1,000 W. Six NEMA 5-15R outlets with battery backup and six with surge protection only. SpecsA NUT 2.8.5 report shows battery data and UPS status via usbhid-ups. Voltage and load readings went missing after one NUT restart and returned after another. USB report
230 V Schuko towerCyberPower CP1500EPFCLCD1,500 VA / 900 W. Six battery-backed Schuko outlets on the European model shown. SpecsThe NUT 2.7.3 report lists shutdown.return and records a shutdown test with usbhid-ups. Device report
230 V rack or towerEaton 5SC2200IRT2,200 VA / 1,980 W. C20 input, eight C13 outlets and one C19 outlet. SpecsThe NUT 2.7.4 report lists battery charge, runtime and the shutdown.return command with usbhid-ups. Device report

Match the UPS to your load

Match the exact model number, voltage and outlet type before ordering. Add the wattage of the devices that need battery backup. Then check the manufacturer’s runtime at that load and leave enough time for your system to shut down. CyberPower sizing guide, NUT shutdown guidance

On the CP1500PFCLCDa, half of the 1,000 W rating is 500 W. CyberPower lists approximately 10 minutes at that load with a new, fully charged battery under normal conditions. Use the runtime at your own load when comparing models. CP1500PFCLCDa runtime specifications

Verify USB monitoring and shutdown support

Connect the UPS to your NUT host over USB. For a single USB UPS, add this section to ups.conf, then start the driver and the upsd data server. NUT driver manual, NUT configuration notes

[myupsname]
    driver = usbhid-ups
    port = auto

Run these read-only checks on the host. Substitute your section name for myupsname if it differs.

upsc myupsname@localhost ups.status
upsc myupsname@localhost
upscmd -l myupsname@localhost
  • The first command reads power status. Look for OL on utility power. OB means the UPS is on battery. NUT status check
  • The second lists available readings. Look for driver.name: usbhid-ups and any battery data you need, such as battery.charge or battery.runtime. Available readings vary by model. NUT configuration notes, NUT driver manual
  • The third lists instant commands. Look for shutdown.return, which the Eaton report lists for cutting power to the load and restoring it when power returns. Confirm the actual behavior with the shutdown test below. NUT command listing, NUT device command example

If you depend on automatic shutdown, configure upsmon. The test can cut power to attached gear. Follow NUT’s shutdown test with utility power absent. Check that the host shuts down before the UPS cuts output, that output returns with utility power, and that the host starts again. NUT shutdown test procedure, USB driver shutdown guidance

Evidence and limits. Specs come from CyberPower and Eaton. The commands follow NUT 2.8.5 documentation, and compatibility details come from model-specific reports published by the NUT project. No hardware or commands were tested for this guide.

Sources

  1. CyberPower CP1500PFCLCDa specifications
  2. NUT issue #2854, CP1500PFCLCDa USB report
  3. CyberPower CP1500EPFCLCD specifications
  4. NUT Device Data Library, CP1500EPFCLCD
  5. Eaton UPS Selector, 5SC 2200i Rack/Tower
  6. NUT Device Data Library, Eaton 5SC 2200i RT
  7. CyberPower UPS buying guide
  8. NUT 2.8.5 usbhid-ups manual
  9. NUT 2.8.5 configuration notes
  10. NUT 2.8.5 upscmd manual