Start with the CyberPower CP1500PFCLCDa for a 120 V tower. For 230 V, choose the CyberPower CP1500EPFCLCD if you need Schuko outlets or the Eaton 5SC2200IRT if you need a rack-mount unit. Compare their power ratings and reported support in Network UPS Tools (NUT) below.
Pure sine wave UPS shortlist
| Best fit | Model | Power and outlets | What NUT reports show |
|---|---|---|---|
| 120 V tower | CyberPower CP1500PFCLCDa | 1,500 VA / 1,000 W. Six NEMA 5-15R outlets with battery backup and six with surge protection only. Specs | A NUT 2.8.5 report shows battery data and UPS status via usbhid-ups. Voltage and load readings went missing after one NUT restart and returned after another. USB report |
| 230 V Schuko tower | CyberPower CP1500EPFCLCD | 1,500 VA / 900 W. Six battery-backed Schuko outlets on the European model shown. Specs | The NUT 2.7.3 report lists shutdown.return and records a shutdown test with usbhid-ups. Device report |
| 230 V rack or tower | Eaton 5SC2200IRT | 2,200 VA / 1,980 W. C20 input, eight C13 outlets and one C19 outlet. Specs | The NUT 2.7.4 report lists battery charge, runtime and the shutdown.return command with usbhid-ups. Device report |
Match the UPS to your load
Match the exact model number, voltage and outlet type before ordering. Add the wattage of the devices that need battery backup. Then check the manufacturer’s runtime at that load and leave enough time for your system to shut down. CyberPower sizing guide, NUT shutdown guidance
On the CP1500PFCLCDa, half of the 1,000 W rating is 500 W. CyberPower lists approximately 10 minutes at that load with a new, fully charged battery under normal conditions. Use the runtime at your own load when comparing models. CP1500PFCLCDa runtime specifications
Verify USB monitoring and shutdown support
Connect the UPS to your NUT host over USB. For a single USB UPS, add this section to ups.conf, then start the driver and the upsd data server. NUT driver manual, NUT configuration notes
[myupsname]
driver = usbhid-ups
port = auto
Run these read-only checks on the host. Substitute your section name for myupsname if it differs.
upsc myupsname@localhost ups.status
upsc myupsname@localhost
upscmd -l myupsname@localhost
- The first command reads power status. Look for
OLon utility power.OBmeans the UPS is on battery. NUT status check - The second lists available readings. Look for
driver.name: usbhid-upsand any battery data you need, such asbattery.chargeorbattery.runtime. Available readings vary by model. NUT configuration notes, NUT driver manual - The third lists instant commands. Look for
shutdown.return, which the Eaton report lists for cutting power to the load and restoring it when power returns. Confirm the actual behavior with the shutdown test below. NUT command listing, NUT device command example
If you depend on automatic shutdown, configure upsmon. The test can cut power to attached gear. Follow NUT’s shutdown test with utility power absent. Check that the host shuts down before the UPS cuts output, that output returns with utility power, and that the host starts again. NUT shutdown test procedure, USB driver shutdown guidance
Evidence and limits. Specs come from CyberPower and Eaton. The commands follow NUT 2.8.5 documentation, and compatibility details come from model-specific reports published by the NUT project. No hardware or commands were tested for this guide.