Illustrated title card for the guide: Eaton 5SC/5P vs CyberPower PFC vs APC Smart-UPS for NUT

ups comparisons

Eaton 5SC/5P vs CyberPower PFC vs APC Smart-UPS for NUT

Compare USB telemetry from Eaton 5SC and 5P, CyberPower PFC and APC Smart-UPS. See which NUT fields each report shows and how to check yours on Linux.

For direct USB monitoring on Linux, NUT lists usbhid-ups for USB connections to Eaton 5SC and 5P, CyberPower CP1500PFCLCD and select APC Smart-UPS models. If you need live watts, shortlist the Eaton 5SC 750 and 5P 650. Both have device reports with ups.realpower. NUT compatibility list, 5SC 750 report, 5P 650 reports.

What each UPS reports over USB

Each report below shows ups.status, battery.charge, battery.runtime and ups.load. The extra fields come from the named unit’s report. The USB HID driver manual says the amount of data varies by manufacturer and model.

UPS in the NUT device libraryExtra fields in the USB HID report
Eaton 5SC 750ups.realpower, ups.power, input.frequency
Eaton 5P 650ups.realpower, ups.power, outlet.1.status, outlet.2.status
CyberPower CP1500PFCLCD (reports with USB vendor ID 0764 and product ID 0501)battery.runtime.low, ups.realpower.nominal
APC Smart-UPS 1500 (NUT 2.7.2 USB HID report)battery.temperature, output.frequency, input.transfer.reason

If those four core fields are enough, all four examples are candidates. Before buying, check the exact model and connection in the compatibility list. For example, the list names APC’s SMT1500I under USB HID, while the table above describes a report labeled Smart-UPS 1500.

Read the telemetry on Linux

This manual example assumes NUT and its usbhid-ups driver are installed, the driver can access one compatible UPS connected by USB, and the upsd data server is configured to listen on localhost. Add this section to ups.conf. usbhid-ups requires the port setting and ignores its value when matching the device. NUT configuration notes, USB HID driver manual.

[myups]
    driver = usbhid-ups
    port = auto

For a manual setup, start the driver with upsdrvctl start, then start the configured data server with upsd. NUT configuration notes.

Run these read-only commands on the NUT server. The first lists UPS names, the second reads the power status, and the last lists all available fields. Use the name shown by the first command if your section has a different name. NUT upsc manual.

upsc -l
upsc myups@localhost ups.status
upsc myups@localhost
  • Power state. Look for OL on line power. OB means on battery and LB means low battery. NUT configuration notes.
  • Battery. Read battery.charge as a percentage and battery.runtime in seconds. NUT variable definitions.
  • Load. Use ups.load for percent, ups.realpower for current watts and ups.power for current volt-amperes. Treat ups.realpower.nominal as nominal watts. NUT variable definitions.

When upsc returns values for your UPS, NUT can read its data. Configure upsmon separately for automatic shutdown. For a UPS with an SNMP management card, see the snmp-ups manual. NUT configuration notes.

Evidence and limits. NUT 2.8.5 documentation and historical NUT device reports were checked on November 26, 2026. The commands were not run on hardware for this guide.

Sources

  1. NUT 2.8.5 hardware compatibility list
  2. NUT device report for Eaton 5SC 750
  3. NUT device reports for Eaton 5P 650
  4. NUT device reports for CyberPower CP1500PFCLCD
  5. NUT device reports for APC Smart-UPS 1500
  6. NUT 2.8.5 usbhid-ups manual
  7. NUT 2.8.5 configuration notes
  8. NUT 2.8.5 upsc manual
  9. NUT 2.8.5 variable definitions
  10. NUT 2.8.5 snmp-ups manual